home *** CD-ROM | disk | FTP | other *** search
/ Magnum One / Magnum One (Mid-American Digital) (Disc Manufacturing).iso / d14 / et4_dyna.arc / ET4_DYNA.EXE / DYNALINK.DOC < prev    next >
Text File  |  1991-04-26  |  3KB  |  83 lines

  1. This disk contains the Beta Version (0.92) DynaLink program for installing the
  2. flicker free parameters for your ProDesigner/e and ProDesigner II.  The
  3. DynaLink can also be used to center the screen in high resolution modes to
  4. tailor for your monitor.
  5.  
  6.  
  7. To install the Dynalink on your hard disk, copy the necessary files from the
  8. floppy diskette to the hard disk.  Use the DOS COPY command to copy the
  9. following files:
  10.  
  11.         STD_MODE.DAT
  12.         DynaLink.COM
  13.  
  14. If you have a ProDesigner/e with Bios Version 1.x, copy the following file
  15. from the floppy drive to your Hard drive:
  16.  
  17.         EXT_MOD1.DAT
  18.  
  19. For the ProDesigner/e with BIOS Version 2.x, copy the following file from the
  20. floppy drive to your Hard drive:
  21.  
  22.         EXT_MOD2.DAT
  23.  
  24. If you have a ProDesigner II with Bios Version 3.x, copy the following file
  25. from drive A to your Hard drive:
  26.  
  27.         EXT_MOD3.DAT
  28.  
  29. For the ProDesigner II with BIOS Version 4.x, copy the following file from
  30. drive A to your Hard drive:
  31.  
  32.         EXT_MOD4.DAT
  33.  
  34.  
  35. NOTE: The BIOS Version is displayed on the ORCHID LOGO boot-up message.
  36.  
  37.  
  38.  
  39.  
  40. You can then install the DynaLink by typing the command:
  41.         DYNALINK -i <drive>
  42. Please refer to section below for details explanation of the parameters.
  43.  
  44.  
  45.  
  46.  
  47. REQUIREMENT:
  48. 1. For ProDesigner II you will need the BIOS version 3.1 or above.
  49. 2. To run the flicker free 800x600 in 70Hz with the ProDesigner/e, you must
  50.    have 512k of video card memory.
  51.  
  52.  
  53.  
  54.  
  55.  
  56. DynaLink Screen Parameters:
  57. ----------------------------------
  58. DynaLink.Com can be called with these parameters:
  59.  
  60. -i <drive> : Install the DynaLink.Com and modify the autoexec.bat file in
  61.              the specified drive.
  62.  
  63. -u <drive> : Uninstall DynaLink.Com from the Autoexec.bat file
  64.              (automatically delete the "DynaLink -on" line from the
  65.              Autoexec.bat file).
  66.  
  67. -on        :  Load the DynaLink flicker free Parameter into memory.
  68.               Remember that DynaLink must be installed prior to using this
  69.               command (DynaLink -i) to insure that the proper Ext_Modx.Dat
  70.               file is accessed.
  71.  
  72. -off        : Reset to the standard ProDesigner (II or /e) BIOS Parameter.
  73.               If, for some reason, you have problems running a particular
  74.               program you may want to use the original ProDesigner (II or
  75.               /e) BIOS parameter. The "DynaLink -off" parameter will
  76.               turn off the flicker free parameters with parameters in the
  77.               BIOS.
  78.  
  79. -s          : This is the DynaLink status flag. It will report any optional
  80.               flicker free parameters that have been installed.
  81.  
  82.  
  83.